Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 416(9): 2137-2150, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37269306

RESUMO

Two-dimensional (2D) materials hold great promise for future applications, notably their use as biosensing channels in the field-effect transistor (FET) configuration. On the road to implementing one of the most widely used 2D materials, graphene, in FETs for biosensing, key issues such as operation conditions, sensitivity, selectivity, reportability, and economic viability have to be considered and addressed correctly. As the detection of bioreceptor-analyte binding events using a graphene-based FET (gFET) biosensor transducer is due to either graphene doping and/or electrostatic gating effects with resulting modulation of the electrical transistor characteristics, the gFET configuration as well as the surface ligands to be used have an important influence on the sensor performance. While the use of back-gating still grabs attention among the sensor community, top-gated and liquid-gated versions have started to dominate this area. The latest efforts on gFET designs for the sensing of nucleic acids, proteins and virus particles in different biofluids are presented herewith, highlighting the strategies presently engaged around gFET design and choosing the right bioreceptor for relevant biomarkers.


Assuntos
Técnicas Biossensoriais , Grafite , Ácidos Nucleicos , Transistores Eletrônicos , Proteínas , Biomarcadores , Técnicas Biossensoriais/métodos
2.
Anal Bioanal Chem ; 414(1): 103-113, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33616686

RESUMO

Point-of-care (POC) technologies and testing programs hold great potential to significantly improve diagnosis and disease surveillance. POC tests have the intrinsic advantage of being able to be performed near the patient or treatment facility, owing to their portable character. With rapid results often in minutes, these diagnostic platforms have a high positive impact on disease management. POC tests are, in addition, advantageous in situations of a shortage of skilled personnel and restricted availability of laboratory-based analytics. While POC testing programs are widely considered in addressing health care challenges in low-income health systems, the ongoing pandemic of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections could largely benefit from fast, efficient, accurate, and cost-effective point-of-care testing (POCT) devices for limiting COVID-19 spreading. The unrestrained availability of SARS-CoV-2 POC tests is indeed one of the adequate means of better managing the COVID-19 outbreak. A large number of novel and innovative solutions to address this medical need have emerged over the last months. Here, we critically elaborate the role of the surface ligands in the design of biosensors to cope with the current viral outbreak situation. Their notable effect on electrical and electrochemical sensors' design will be discussed in some given examples. Graphical abstract.


Assuntos
Antígenos Virais/análise , Técnicas Biossensoriais/métodos , Teste para COVID-19/métodos , COVID-19/diagnóstico , Testes Imediatos/tendências , SARS-CoV-2/imunologia , Antígenos Virais/imunologia , COVID-19/virologia , Técnicas Eletroquímicas , Humanos , Ligantes , Sistemas Automatizados de Assistência Junto ao Leito
3.
Anal Bioanal Chem ; 414(18): 5319-5327, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34595559

RESUMO

Sensitive and selective detection of biomarkers in serum in a short time has a significant impact on health. The enormous clinical importance of developing reliable methods and devices for testing serum levels of cardiac troponin I (cTnI), which are directly correlated to acute myocardial infarction (AMI), has spurred an unmatched race among researchers for the development of highly sensitive and cost-effective sensing formats to be able to differentiate patients with early onset of cardiac injury from healthy individuals with a mean cTnI level of 26 pg mL-1. Electronic- and electrochemical-based detection schemes allow for fast and quantitative detection not otherwise possible at the point of care. Such approaches rely largely on voltammetric and field-effect-based readouts. Here, we systematically investigate electric and electrochemical point-of-care sensors for the detection of cTnI in serum samples by using the same surface receptors, cTnI aptamer-functionalized CVD graphene-coated interdigated gold electrodes. The analytical performances of both sensors are comparable with a limit of detection (LoD) of 5.7 ± 0.6 pg mL-1(electrochemical) and 3.3 ± 1.2 pg mL-1 (electric). However, both sensors exhibit different equilibrium dissociation constant (KD) values between the aptamer-linked surface receptor and the cTnI analyte, being 160 pg mL-1 for the electrochemical and about three times lower for the electrical approach with KD = 51.4 pg mL-1. This difference is believed to be related to the use of a redox mediator in the electrochemical sensor for readout. The ability of the redox mediator to diffuse from the solution to the surface via the cTnI/aptamer interface is hindered, correlating to higher KD values. In contrast, the electric readout has the advantage of being label-free with a sensing limitation due to ionic strength effects, which can be limited using poly(ethylene) glycol surface ligands.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Biomarcadores , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Humanos , Limite de Detecção , Troponina I
4.
Nanomaterials (Basel) ; 11(10)2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-34684969

RESUMO

In this work, we have investigated the influence of the transfer process on the monocrystalline graphene in terms of quality, morphology and electrical properties by analyzing the data obtained from optical microscopy, scanning electron microscopy, Raman spectroscopy and electrical characterizations. The influence of Cu oxidation on graphene prior to the transfer is also discussed. Our results show that the controlled bubbling electrochemical delamination transfer is an easy and fast transfer technique suitable for transferring large single crystals graphene without degrading the graphene quality. Moreover, Raman spectroscopy investigation reveals that the Cu surface oxidation modifies the strain of the graphene film. We have observed that graphene laying on unoxidized Cu is subject to a biaxial strain in compression, while graphene on Cu oxide is subject to a biaxial strain in tension. However, after graphene was transferred to a host substrate, these strain effects were strongly reduced, leaving a homogeneous graphene on the substrate. The transferred single crystal graphene on silicon oxide substrate was used to fabricate transmission line method (TLM) devices. Electrical measurements show low contact resistance ~150 Ω·µm, which confirms the homogeneity and high quality of transferred graphene.

5.
Nanoscale Horiz ; 6(10): 819-829, 2021 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-34569584

RESUMO

The controlled covalent functionalization of the graphene channel of a field effect transistor, based on interdigitated gold electrodes (source and drain), via electrochemical grafting, using specifically designed aryl diazonium species is demonstrated to allow the simple fabrication of a general platform for (bio)sensing applications. The electrochemical grafting of a protected ethynylphenyl diazonium salt leads to the deposition of only a monolayer on the graphene channel. This controlled covalent functionalization of the graphene channel results in a charge mobility of the GFET of 1739 ± 376 cm2 V-1 s-1 and 1698 ± 536 cm2 V-1 s-1 for the holes and electrons, respectively, allowing their utilization as (bio)sensors. After deprotection, a dense and compact ethynylphenyl monolayer is obtained and allows the immobilization of a wide range of (bio)molecules by a "click" chemistry coupling reaction (Huisgen 1,3-dipolar cycloaddition). This finding opens promising options for graphene-based (bio)sensing applications.


Assuntos
Grafite , Química Click , Reação de Cicloadição , Eletrodos , Ouro
6.
Anal Bioanal Chem ; 413(3): 779-787, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32816088

RESUMO

Several challenging biological sensing concepts have been realized using electrolyte-gated reduced graphene oxide field effect transistors (rGO-FETs). In this work, we demonstrate the interest of rGO-FET for the sensing of human papillomavirus (HPV), one of the most common sexually transmitted viruses and a necessary factor for cervical carcinogenesis. The highly sensitive and selective detection of the HPV-16 E7 protein relies on the attractive semiconducting characteristics of pyrene-modified rGO functionalized with RNA aptamer Sc5-c3. The aptamer-functionalized rGO-FET allows for monitoring the aptamer-HPV-16 E7 protein binding in real time with a detection limit of about 100 pg mL-1 (1.75 nM) for HPV-16 E7 from five blank noise signals (95% confidence level). The feasibility of this method for clinical application in point-of-care technology is evaluated using HPV-16 E7 protein suspended in saliva and demonstrates the successful fabrication of a promising field effect transistor biosensor for HPV diagnosis.Graphical abstract.


Assuntos
Grafite/química , Papillomavirus Humano 16/isolamento & purificação , Infecções por Papillomavirus/diagnóstico , Saliva/virologia , Transistores Eletrônicos , Infecções Tumorais por Vírus/diagnóstico , Aptâmeros de Nucleotídeos , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Estudos de Viabilidade , Humanos , Limite de Detecção , Proteínas E7 de Papillomavirus , Infecções por Papillomavirus/virologia , Análise Espectral/métodos , Infecções Tumorais por Vírus/virologia
7.
Nanotechnology ; 28(33): 335702, 2017 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-28726682

RESUMO

In this paper, a broadband non-destructive and non-contact local characterization of graphene fabricated by epitaxial method on silicon carbide is demonstrated by using an interferometer-based near-field microwave microscope. First, a method has been proposed to extract the dielectric properties of silicon carbide, and finally, the graphene flake has been characterized as a resistance (∼20 kΩ) and a small inductance (360 pH) in the frequency band (2-18 GHz). The advantage of the proposed method is that there is no need to fabricate electrodes on the sample surface for the characterization. The instrument proposed is a good candidate for the local characterization of 2D materials.

8.
Nanoscale ; 8(29): 14097-103, 2016 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-27396243

RESUMO

Graphene has been regarded as a promising candidate channel material for flexible devices operating at radio-frequency (RF). In this work we fabricated and fully characterized double bottom-gate graphene field effect transistors on flexible polymer substrates for high frequency applications. We report a record high as-measured current gain cut-off frequency (ft) of 39 GHz. The corresponding maximum oscillation frequency (fmax) is 13.5 GHz. These state of the art high frequency performances are stable against bending, with a typical variation of around 10%, for a bending radius of up to 12 mm. To demonstrate the reliability of our devices, we performed a fatigue stress test for RF-GFETs which were dynamically bend tested 1000 times at 1 Hz. The devices are mechanically robust, and performances are stable with typical variations of 15%. Finally we investigate thermal dissipation, which is a critical parameter for flexible electronics. We show that at the optimum polarization the normalized power dissipated by the GFETs is about 0.35 mW µm(-2) and that the substrate temperature is around 200 degree centigrade. At a higher power, irreversible degradations of the performances are observed. Our study on state of the art flexible GFETs demonstrates mechanical robustness and stability upon heating, two important elements to assess the potential of GFETs for flexible electronics.

9.
Biosens Bioelectron ; 50: 239-43, 2013 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-23871871

RESUMO

The paper reports on a surface plasmon resonance (SPR)-based approach for the sensitive and selective detection of lysozyme. The SPR sensor consists of a 50 nm gold film coated with a thin film of reduced graphene oxide (rGO) functionalized with anti-lysozyme DNA aptamer. The SPR chip coating with rGO matrix was achieved through electrophoretic deposition of graphene oxide (GO) at 150 V. Electrophoretic deposition resulted in partial reduction of GO to rGO with a thickness depending on the deposition time. For very short time pulses of 20 s, the resulting rGO film had a thickness of several nanometers and was appropriate for SPR sensing. The utility of the graphene-based SPR sensor for the selective and sensitive detection of proteins was demonstrated using lysozyme as model protein. Functionalization of rGO matrix with anti-lysozyme DNA aptamer through π-stacking interactions allowed selective SPR detection of lysozyme. The graphene-based SPR biosensor provides a means for the label-free, concentration-dependent and selective detection of lysozymes with a detection limit of 0.5 nM.


Assuntos
Aptâmeros de Nucleotídeos/química , Grafite/química , Muramidase/análise , Ressonância de Plasmônio de Superfície/instrumentação , Limite de Detecção , Óxidos/química , Propriedades de Superfície
10.
Analyst ; 138(15): 4345-52, 2013 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-23730686

RESUMO

Conducting interfaces modified with reduced graphene oxide (rGO) have shown improved electrochemical response for different analytes. The efficient formation of functionalized rGO based materials is thus of current interest for the development of sensitive and selective biosensors. Herein, we report a simple and environmentally friendly method for the formation of a hemin-functionalized rGO hybrid nanomaterial that exhibits remarkable sensitivity to peroxynitrite (ONOO(-)) in solution. The hemin-functionalized rGO hybrid nanomaterial was formed by mixing an aqueous solution of graphene oxide (GO) with hemin and sonicating the suspension for 5 h at room temperature. In addition to playing a key role in biochemical and electrocatalytic reactions, hemin has been proven to be a good reducing agent for GO. The sensitivity of the peroxynitrite sensor is ≈7.5 ± 1.5 nA mM(-1) with a detection limit of 5 ± 1.5 nM.


Assuntos
Grafite/química , Hemina/química , Óxidos/química , Ácido Peroxinitroso/química , Espectroscopia Fotoeletrônica/métodos
11.
Nano Lett ; 12(3): 1184-8, 2012 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-22283460

RESUMO

Flexible electronics mostly relies on organic semiconductors but the limited carrier velocity in polymers and molecular films prevents their use at frequencies above a few megahertz. Conversely, the high potential of graphene for high-frequency electronics on rigid substrates was recently demonstrated. We conducted the first study of solution-based graphene transistors at gigahertz frequencies, and we show that solution-based single-layer graphene ideally combines the required properties to achieve high speed flexible electronics on plastic substrates. Our graphene flexible transistors have current gain cutoff frequencies of 2.2 GHz and power gain cutoff frequencies of 550 MHz. Radio frequency measurements directly performed on bent samples show remarkable mechanical stability of these devices and demonstrate the advantages of solution-based graphene field-effect transistors over other types of flexible transistors based on organic materials.


Assuntos
Grafite/química , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Transistores Eletrônicos , Cristalização/métodos , Módulo de Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Tamanho da Partícula , Soluções
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...